diff --git a/docs/troubleshooting.txt b/docs/troubleshooting.txt
index 459143e..315f9f4 100644
--- a/docs/troubleshooting.txt
+++ b/docs/troubleshooting.txt
@@ -373,8 +373,27 @@ Storage
or again we can compare lvm volumes which are used by Gluster bricks and which are not. The later
ones should be cleaned up. Again there is the script.
+ - Status of RAID can be checked with storcli utility
+ /opt/MegaRAID/storcli/storcli64 /c0/v0 show
+ /opt/MegaRAID/storcli/storcli64 /c0 show
+ to further check smart attributes of a specific disk, one first needs find a corresponding DID of the
+ disk. This is reported by storcli64 in JSON output mode
+ /opt/MegaRAID/storcli/storcli64 /c0 /eall /sall show j
+ Then, smartmontools can be used to extract smart attributes from this disk
+ smartctl --all --device megaraid,<DID> /dev/sda
+
MySQL
=====
+ - MySQL may stop connecting to the master. While correct username and password are set in the container
+ environment, mysql slave actually uses values stored somewhere in the database. It seems occasionally
+ a corruption might happen causing authentication to break and slave report error 1045
+ Error connecting to master. retry-time: retries: 1, Error_code: 1045
+ The work-around is to set correct username/password again (using the values from environment):
+ STOP SLAVE;
+ CHANGE MASTER TO MASTER_USER='replication' MASTER_PASSWORD='...';
+ START SLAVE;
+ This should fix it and the new username/password will be remembered over restarts...
+
- MySQL may stop replicating from the master. There is some kind of deadlock in multi-threaded SLAVE SQL.
This can be seen by exexuting (which should show a lot of slave threads waiting on coordinator to provide
the load).
diff --git a/log.txt b/log.txt
new file mode 100644
index 0000000..209b924
--- /dev/null
+++ b/log.txt
@@ -0,0 +1 @@
+ - ipekatrin1: Replaced disak in section 9. LSI software reports all is OK, but hardware led indicates a error (red). Probably indicator is broken.